Fluke 17B+ Digital Multimeter Fluke17B+

Fluke 17B+ Digital Multimeter Fluke17B+
Mağaza: hepsiburada
Son Fiyatı: 5190.00 TL

Benzer Ürünler

Satıcıdan aynı kategoride diğer ürünler

Tümü

Ürün bilgileri

Fluke 17B+ Digital Multimeter Fluke17B+ Function Range Resolution Accuracy AC volts (40 Hz to 500Hz)1 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 DC volts 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 0.5 % + 3 AC millivolts 400.0 mV 0.1 mV 3.0 % + 3 DC millivolts 400.0 mV 0.1 mV 1.0 % + 10 Diode test2 2.000 V 0.001 V 10% Resistance (Ohms) 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 Capacitance3 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 Frequency1 Hz (10 Hz – 100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz 0.1 % + 3 Duty Cycle1 1 % to 99 % 0.1 % 1 % typical 4 AC current μA (40 Hz to 400 Hz) 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3 AC current mA (40 Hz to 400 Hz) 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3 AC current A (40 Hz to 400 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 DC current μA 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3 DC current mA 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3 DC current A 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 Temperature 50 °C- 400 °C 0 °C- 50 °C -55 °C- 0 °C 0.1C 2 % ± 1 °C ± 2 °C 9 % ± 2 °C Backlight - - Yes 1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %. Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc, 50 Hz or 60 Hz - AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz - DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz - 1 106 V Hz Max General Specifications Maximum voltage between any terminal and earth ground 1000 V Display (LCD) 4000 counts, updates 3/sec Battery type 2 AA, NEDA 15A, IEC LR6 Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.) Temperature Operating 0 °C to 40 °C Storage -30 °C to 60 °C Relative Humidity Operating humidity Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C; ≤75% RH at 30 °C to 40 °C 40 MΩ range ≤80% RH at 10 °C to 30 °C; ≤70% RH at 30 °C to 40 °C Altitude Operating 2000 m Storage 12,000 m Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or>28 °C) Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only. Size (HxWxL) 183 x 91 x 49.5 mm Weight 455 g IP rating IP 40 Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2 Electromagnetic environment IEC 61326-1: Portable Electromagnetic compatibility Applies to use in Korea only

Fiyat Geçmişi

Dönem içi en ucuz fiyat: 23 Ocak 2022 tarihinde 2699

Dönem içi en pahalı fiyat: 29 Ocak 2023 tarihinde 5190