1. hepsiburada
  2. Yapı Market Bahçe Oto
  3. Yapı Market ve Hırdavat
  4. Ölçüm Cihazları
  5. Multimetre

Fluke 106 Dijital Multimetre

Fluke 106 Dijital Multimetre
Mağaza: hepsiburada
Son Fiyatı: 2300.00 TL

Benzer Ürünler

Satıcıdan aynı kategoride diğer ürünler

Tümü

Ürün bilgileri

Fluke 106 Dijital Multimetre Accuracy Specifications Function Range Resolution Accuracy AC Volts1 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 1.0 % + 3 DC Volts 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 0.5 % + 3 AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3 Diode Test2 2.000 V 0.001 V 10 % Resistance (Ohms) 400.0 O 4.000 kO 40.00 kO 400.0 kO 4.000 MO 40.00 MO 0.1 O 0.001 kO 0.01 kO 0.1 kO 0.001 MO 0.01 MO 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 Capacitance3 50.00 nF 500.0 nF 5.000 µF 50.00 µF 500.0 µF 1000 µF 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 1 µF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 Frequency4 Hz (10 Hz – 100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA Duty Cycle4 1 % to 99 % 0.1 % NA AC Current (40 Hz to 200 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 DC Current 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio AC Volts 600 V 1 >10 MO <100 pF 2 >60 dB at dc, 50 Hz or 60 Hz - AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz - DC Volts 600 V 1 >10 MO <100 pF >100 dB at dc, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz 6 x 105 V Hz Max For mV (AC), input impedance is approximately 1 MO. General Specifications Maximum Voltage Between any Terminal and Earth Ground 600 V Display (LCD) 6000 counts, updates 3/sec Battery Type 2 AAA, NEDA 24A, IEC LR03 Battery Life 200 hours minimum Temperature Operating 0 °C to 40 °C Storage -30 °C to 60 °C Relative Humidity Operating Humidity Non-condensing when <10°C =90 % at 10 °C to 30 °C; =75 % at 30 °C to 40 °C Operating Humidity, 40 MO Range =80 % at 10 °C to 30 °C; =70 % at 30 °C to 40 °C Altitude Operating 2000 m Storage 12,000 m Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or>28 °C) Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only Size (HxWxL) 142 mm x 69 mm x 28mm Weight 200 g IP Rating IEC 60529: IP 40 Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2 Electromagnetic Environment IEC 61326-1: Portable Electromagnetic Compatibility Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1

Fiyat Geçmişi

Dönem içi en ucuz fiyat: 24 Kasım 2021 tarihinde 1235

Dönem içi en pahalı fiyat: 23 Nisan 2023 tarihinde 2300